Magnetic contactor

Tesys D-rangem
- 6A ~ 38A (AC3)
- 3P,4P Version
- AC coil
- DC coil
- Àú ¼ÒºñÀü·Â DC(°í°¨µµ):¼ÒºñÀü·Â 2.4W
- Á¤,¿ª ¿îÀü¿ë ¹ö½º¹Ù
- Y-D ¿ë ¹ö½º¹Ù
- ½áÁö ¿É¼­¹ö ³»Àå(DC ÄÚÀÏ)
- 1a,1b º¸Á¶Á¢Á¡
- ¸µ Å͹̳Π- ´Ù¾çÇÑ Á¶ÀÛ Àü¾Ð
- µ¿ÀÏÇÑ Æø : 45 mm
- º¸È£ Ä¿¹ö ±âº»ÀåÂø
- ±¸Çü Á¦Ç°°ú ¾×¼¼¼­¸® 100 % ȣȯ
catalogue
dimension
D-range
- 3 P,4 P version
- 40A~150A @ AC3
- 50A~200A@AC1
- Reversing : LC,LP2-D
- UL/CSA,DEMKO/SEMKO/NEMKO,CE IEC947-4
- Operation voltage : 690VAC
- Ambient temperature : -40C~+70 C
- Control voltage : AC 24V~AC440V DC: 12V~ 220/230V
catalogue1
catalogue2
catalogue3
catalogue4
configuration
dimension
F-range
- Operation voltage: 1,000V
- UL/CSA, DEMKO,SEMKO,NEMKO,BV,GL/LR/

USSR/RINA, IEC 947-4

- 2P, 4P version
- 200A~1,600A@A-C1
- coil Àº ºÐ¸® ÁÖ¹®
- AC control Voltage: 110/220/380/415/ 440V
- DC control Voltage : 110/220/380/415V
- Á¤·ù±â DR5TE4U ´Â LC1F800 Àº Çʼö
configuration
catalogue
reference
accessories
dimension
Bar-mounted Magnetic contactor
- 750~1,800A @AC3
- operational voltage: 1,000VAC,1500VDC
- No.of poles : 1 to 4 N/O
catalogue1
catalogue2
dimension
Latching conatactor
- Latching contactor
- rated operational voltage : 1000VAC, 1500VDC
- No.of poles : 3,4 poles of CR1-F
- No.of poles : 1,2,3,4 poles of CR1-B
catalogue
reference
dimension
Tesys New Contactor
- compact size
- included spark killer
- Universal terminals
- low power consumption
- Aux. contact 1a, 1 b as standard
- wide control voltage

Manual Motor Start(MMS) & MCCB for Motor start product range
GV2ME
- Thermal magnetic protection
- Motor Àü¿ë MCCB
- 0.1~25A (GV2M01~GV2M22)
- 100 kA @440V: GV1M01~GV2M08
- 50 kA @440V : GV2M10
- 15 kA @ 440V : GV2M14
- 8 kA @440V : GV2M16/M20
- 6 kA@440V : GV2M21
- UL/CSA,BV,DNV,GL,LR,KR
catalogue
dimension
GV3M
- Thermal magnetic protection
- Motor Àü¿ë MCCB
- 24A ~ 80A
- 6 kA@440V : GV3M32
- 18.5kA@440V : GV3M40
- 30 kA@440V : GV3M63
- 37 kA@440V : GV3M80
- UL/CSA,BV,DNV,GL,LR,KR
catalogues
configuration
dimension
F-range

- Thermal magnetic protection
- adjustable over load current
- 25 kA@440V : GV7RE
- 70 kA@440V : GV7RS
- 25~220A : GV7RS,RE
- 40 ~220A

catalogues
configuration
dimension
GV2P
- Rotary handle
- Thermal Magnetic protection
- Motor Àü¿ë MCCB
- 100 kA@440V : GV2P01~GV2P14
- 50 kA@440V : GV2P16
- 20 kA@440V : GV2P21~GV2P22
- UL/CSA,BV,DNV,GL,LR
catalogue
dimension
GV2LS,GV3LS
GV2LE,GV2L,GK3EF
Circuit Protector CP / GB2CB,CDr
- Thermal Magnetic protection for control circuit
- 1P : 0.5~12A
- 2P : 0.5~12A
- Im = 13 In : GB2CB,CD
- Im = 6 In : GV2CS (0.5,1A,1P)
- UL/CSA,NEMKO :GB2-CB
- ASE/NEMKO,IEC947-2,EN60947-1 : GB2-CD
- applications : solenoid V/V, electro-brake,battery

charger,Trs

catalogue1
catalogue2

Switch & Fused switches
Vario Switch-Disconnector
- UL/CSA,ASE,GL,CE,IEC-947-3
- operational voltage : 690 V
- Add-on module, Netural module, earthing module,

Aux contact

- Extended rotary handle/direct handle
- Black & emergency switch
- Loas break switch
catalogue1
catalogue2
catalogue3
catalogue4
configuration&reference
dimension1
dimension2
dimension3
dimension4
GV3M
- 3P, 4P version
- For NF c or DIN fuses
- Internal, external, side ,front mounting
- shaft extension
- cage terminal for connection to bare cables
- Blown fuse signalling contact
- Aux. early break and signalling of position
(on,off)
catalogue1
catalogue2
catalogue3
dimension1
dimension2
dimension3
dimension4

Measurement Relay product range
Measurement ,Protection Relay
- Over current relay : RM4-JA2(0.003~1A)
- Under current + Over current relay
 : RM4-JA1(0.003~1A,0.3~15A)
- Over voltage(AC,DC)
 : RM4-UA2 (adjuable 0.05~5V,1~100V,30~500V)
- Rotational direction of phases : RM3-TG2, 200~500VAC
- Rotational direction & total failure of one or more phases
 : RM3-TR1
-
Asymetric of phase,failure : RM3-TA
- Asymetric of phases,failure, rotational direction of phase
 : RM3-TAR1
- Liquid level measurement(1C/O): RM3-LG2
- Liquid level measurement(2C/O): RM3-LA1
- Insulation control : RM3-PA1, 1~100Kohm
- Control of contact closing : RM3-EA1
product range
catalogue1
catalogue2
catalogue3
catalogue4
catalogue5
Interface Relay
- For discrete signal : ABR-1E,-2E(input),

ABR-1S,2S(output)

- Solid state interface modules : ABS-1E,-2E (input),

ABS-1S,-2S(output)

- Supply voltage : 24VADC,48VADC,110VDC, 115~127VAC,

230~240VAC

catalogue1
catalogue2
catalogue3
catalogue4
Control Relay
- instantaneous : CAD
- Memory : CA2-DK
- instantneous,low comsumption:
catalogue
dimension
TOR, LR2D
- Fault detected: Overload,Stalling,phase failure
- 3 element
- manual,auto reset
- class 10
- max.over current : 17 In
- compensated, trip indicator
- For AC,DC supply
product range
catalogue
reference
dimension
setting
LR7D, LR3D, EOCR

 

catalogue
dimension


LR-9F
- Compensated and differential
- with trip indicator
- for use AC and DC
- For direct and separate mounting
- Class 10
- LR-9F5357 : 30~50A
- LR-9F5363: 40~80A
- LR-9F5367 : 60~100A
- LR-9F5369 : 90~150A
- LR-9F5371 : 132~220A
- LR-9F7375 : 200~330A
- LR-9F7379 : 300~500A
- LR-9F7381 : 380~630A
catalogue
reference
dimension
Multi function Relay
- 3 pole multi function protection relay
- CT : 100A,400A,800A
- Toroid sensors: 30 ~300phi
- thermal over load protection
- motor winding overheating protection
- phase unblance/phase loss protection
- ground fault protection
- thermal overload alarm
- Prolonged starting protection byPC
- locked rotor protection
- under load
- power factor monitoring
- phase revesal protection
- PTC : 90 ~ 170 degree C.
catalogue
specification
reference
dimension
connection circuit

Soft-Start
LH4N1,N2
- Soft-start : LH4N1(1.1~11Kw)
- Soft-start,stop: LH4N2 (1.1 ~75 Kw)
- Economic product
- voltage lamp control
- adjustable starting torque: 0.3~0.8 Tn
- adjustable starting time : 1~5/1~25s
- rated voltage : 200~240V/380~415/440~480V +10%-15%
- soft-stop time : 1~5/1~25 sec
- IEC 60947-4-2
- UL/CSA,CE
catalogue1
catalogue2
catalogue3
ATS-48
- TCS(Torque Control )type
- class 10. 20 selectable
- current limiting : 2~7 In
- freewheel, stop controoled by torque lamp, breaked stop

mode

- current adjustment : 0.5~1.3
- UL/CSA,IEC,NF C,VDE,DNV
-
208 V/ 380 V/ 440 V version
- motor power : 2.2 ~800 Kw
- cascading start, stator loss - compensation, voltage boost
- adjustable starting torque : 10%~


Inverter ATV08/28/58/68 (0.18~630 kW) product range 

ATV-11
- 200~240V,1 phase power supply
- Sensorless flux vector control
- Starting and speed control
- inversion of operating direction
- decel,acceleating,stopping
- motor and speed controller protection
- UL/CSA,CE
- output frequency : 0.5~200 Hz
- switching frequency : 4 KHz(auto)
- braking torque : 50 % of nominal motor torque
- max. transient current : 120 % for 20 sec, 150% for 1 sec
- 1 AI, 4 LI,1AO,1 LO
up to 2.2 Kw
½ÅÁ¦Ç°, Àç°íº¸À¯

ATV-28

- 200 ~240 V,1 phase, 200~230 V, 3phase, 380~500V 3phase
- frequency : 50/60Hz +/-5%
- output frequency : 0.5~400 Hz
- max.transient current : 150 % In
- transient over torque : 150~170% Tn
- braking torque : 30 % Tn
- braking module included
- slip compensation : automatic
- V/F control : preset but correction possible
- switching frequency : 2 to 15 KHz
- frequency resolution : 0.1 Hz
- 1AO(4~20mA or 0~20 mA)
- AI : 2 voltage input, 1 current input
- Logic input : 4

- configuration relay : 1
- braking to standstill : DC injection 0~25 sec setting time
- communication : RS 485



Àü¸é Æ÷Å׼ǸÞÅÍ.
Á¶ÀÛ ½ºÀ­Ä¡³»Àå.
PNP, NPN ¼³Á¤.
ATV 38Pump,HVACÀü¿ë

- ÃÖ´ë 315 Kw @ 380~500V
- ºÎ½ºÅÍ ÆßÇÁÀü¿ë Ä«µå(¼±ÅÃ)
- ÃÖ´ë 5´ë±îÁö ÀÚµ¿¿îÀü
- EMC ÇÊÅͳ»Àå(75Kw ±îÁö)
- °æÁ¦ÀûÀÎ °¡°Ý

ATV58
- EMC filter integrated
- High torque(170%Tn), normal torque (120%Tn)
- starting/stopping,dynamic braking, braking to stand

still,speed control

- energy saving, PI regulator
- brake sequence
- speed control loop with tacho,encorder
- +/- speed,S ramp,U ramp,preset speed, jog operation
- UL/CSA,CE
- outut frequency range: 0.1~500Hz
- brake torque : 30 % Tn
- V/F ratio : sensorless flux vector control
- transient over torque : 200 % of Tn for 2 s, 170% of Tn for

60 s

catalogue1
catalogue2
catalogue3
dimesion1
dimesion2
ATV58
- C ,EN, NF C, VDE, UL,CSA,CE
- 0.75~55 Kw
- output frequency : 0~450 Hz
- switching frequency : 0.5~12 depend on model.
- speed range : 1 ~ 1000 closed loop with encoder,

1~100 open loop

- speed precision : +/- 1%
- Trasient over torque : 200 % for 2 sec,170% for 60 sec
- braking torke : 30 % of Tn
- V/F ratio : Flux vector control with or without sensor
- acceleration and deceleration ramps: linear, S,U or totally

customerized

- Time : 0.01 to 999.9 secs
- communication : RS-485
- type of encoder : incremental, Rs-422 compatiable,

max 5000 /rev,min 100/rev.

º¤ÅÍÇü ÀιöÅÍ
ATV68
- ATV68F : Flux vector control with sensor , with integrated

encoder feedback card

- standard torque : 120 % Tn
- high torque : 150 % Tn
- dual configuration(2motors)
- integrated PID controller
- 7 possible preset speeds
- jog operation
- brake release sequence for transient movement and oisting
- user defineable analog and logic inputs
- +/- speed
- skip frequency
- compare function
- logic function
- starting and speed regulation via flux vector control
- protection of motor speed
- auto tunning
- high over torque on start -up
- separate 24V supply for control circuit
- switching frequency : 2.5-5-10 KHz
 

Swithes, Push button, Sensors  

Pendant switch
- single speed hoist motors : XAC-A1
- 2 speed hoist motor : XAC-A2
- intuitive operation,power circuit : XAC-D(single, 2 speed)
- mechanical endurance : 1¹é¸¸È¸
- UL/CSA,IEC
- 2 ±¸ ~12 ±¸
product range
catalogue1
catalogue2
catalogue3
catalogue4
catalogue5

Hot-delivery °¡´É!
CAM switch

- switches with 45 deg switching angle
- On-OFF switches
- stepping switches with "0 "
- stepping switch without "0 "
- Reversing switchs 1~4P
- ammeter switches
- volt meter switches

catalogue1
catalogue2
catalogue3
catalogue4
catalogue5
catalogue6
catalogue7
circuit
Harmony XB-6

- natural colour
- modular configuration
- protected LED type
- IP 65
- double insulated bezel
- PL, PBS,PBL
- LED : 12 ~24V,110/230VAC neon,24VADC incandescend bulb
- 1 N.O +1 N.C

catalogue1
catalogue2
catalogue3
catalogue4
dimension
Harmony XB-4

- UL/CSA,JIS,IEC,
- IP 65

- metal bezel,chromium plated
- modular type
- max 8 contact ( 4 N.O+4 N.C)
- Protected LED type PL
- Neon, BA9s lamp
- 24VADC, 230~240VAC, double insulated bezel
- 30 phi ´Â ¹®ÀÇ¿ä¸Á
- (Àç°íÇ׽ú¸À¯)

catalogue1
catalogue2
catalogue3
catalogue4
catalogue5
dimension
Harmony XB-5
- UL/CSA,JIS,IEC,
- IP 65
- plastic bezel
- modular type
- max 8 contact ( 4 N.O+4 N.C)
- Protected LED type PL
- Neon, BA9s lamp
- 24VADC, 230~240VAC,double insulated bezel
- (Àç°íÇ׽ú¸À¯)
catalogue1
catalogue2
catalogue3
catalogue4
dimension
Proximity switch
- metal case(brass) M8 x1,DC supply
- flush montable in metal or non flush mountable in metal
- plastic case M8, AC or DC supply
- M4
-
M8
-
M12
-
M18
-
M30
product range
introduction
Photo sensor/Orisis
- Fiber design : XUD-H
-
Compact design : XUE-H
- Compact design : XUJ-LM
- Compact design : XUJ-K
- Compact design ,pre-cabled : XUL-H
- design18,plastic,M18,sensitivity adjument : XU
- design18,metal case M18x1 : XU1-
- design8,pre-cabled,M8x1,metal : XUA-H
- miniature,rectangular : XUM-L
- XUM-H
- XUB
product range
introduction

Limit switch
- double insulated
- CSA,UL,NEMKO,IEC,CE
- plunger,rotary,multi directional, conveyor belt monitoring,

hoisting and mechanical,

- XCK-P : 1 cable entry
- XCK-T : 2cable entries
- XCK-S : 1 cable entry
- XCK-M : metal,fixed type,3 cable
- XCM : pre-cabled,metal,compact
- XCK-J : metal,fixed,1 cable entry
- XC2-J : user assembled 1 cable, metal fixed
- XCK-ML : metal,2pole contactor,3cable entries
- XC1-AC : mechanical handling applications, 3 cable

entries

- XCR : hoisting, 1 cable entry
- XCR-T : conveyor belt monitoring
product range
XCK-P 1
XCK-P 2
XCK-T ±¸¼º
XCK
Pressure& Vacuum switches
- electro mechanical pressure switch
- XML-A : fixed differential, single threshold detection :

0.03~500 bar

- XML-B : adjustable differential, 2 threshold with indicator :

0.3~ 500 bar

- XML-AM: vacuum switch
- XML-BM: vacuum switch
- XML-BM : vacuum + pressure switch
specification
2.5 bar
4 bar
10 bar
20 bar
35 bar
70 bar
160 bar
300 bar
Rotary Encoder
- opto -electric rotary encoder
- daimeter : 40,58,90 mm
- incremental encoder : XCC-1
- absolute encoder : XCC-2
- resolution : 100 ~1024 for XCC-1
- resolution : 1024~8192 for XCC-2
- 5V Rs-422
 
Zelio Smart Relay SR1
- multi function smart relay
- timers
- counters
- logic input/output
- Time of date function
- ladder programming & direct programming using Keys
- Dc or AC power supply
- Loading & programming using
soft-ware
catalogue